COMFORT

    * The radiant heat provides gentle, even distributed warmth to floors, objects and occupants.
    * No drafts or periodic blasts of hot air, as discovered with conventional forced air heaters.

ECONOMICAL

    * Operates on natural gas or propane for high combustion efficiency.
    * Substantial fuel savings over conventional heating systems.

INSTALLATION

    * Light weight for easy installation
    * Available in 15 to 50 foot lengths
    * Side wall or roof venting

DEPENDABILITY

    * Manufactured with highest quality of materials and workmanship.
    * Engineered for years of trouble-free, low maintenance heating.


CALCANA QUALITY . . .   THE ONLY CHOICE

 GENERAL SPECIFICATIONS

RATING: (Input) (0 - 4500 ft. Above Sea Level)

(Natural and L.P. Gas)
CAL- 50A (Natural Only) 50,000 B.T.U./Hr.
CAL- 75A 75,000 B.T.U./Hr.
CAL- 80A 80,000 B.T.U./Hr.
CAL- 85A 85,000 B.T.U./Hr.
CAL- 100A 100,000 B.T.U./Hr.
CAL- 125A 125,000 B.T.U./Hr.

Gas Pressure at Manifold:
Natural Gas 3.5" W.C.
L.P. Gas 10.5" W.C.
Gas Connection Size 1/2" N.P.T

Gas Inlet Pressure:
GAS MINIMUM MAXIMUM
Nat. 4.5"  W.C. 14.0"  W.C.
L.P. 11.0"  W.C. 14.0"  W.C.
Flue Connection 4"

ELECTRICAL RATING:
120V, 60Hz, .80 Amps
Appliance, 3 prong plug connection
24 Volt Low Voltage Thermostat

SHIPPING WEIGHT: Approximately 85-150 lbs.
 STANDARD EQUIPMENT

Burner control housing is preassembled and prewired complete with the following: industry standard gas, electrical and venting connections, balanced air rotor, thermal overload protected motor, visual burner inspection sight glass, combustion and air proving safety switches, direct spark ignition control, low voltage thermostat connection, three prong appliance plug, 4" aluminized combustion tube. Unassembled pieces include: polished aluminum standard reflector, 4" mild steel radiant heat exchanger, tube couplers, joint pieces, joint/hanger pieces, heat economizer baffle.

OPTIONAL EQUIPMENT:
-Side Reflectors
-Lower Radiant Shield Kit
-Thermostat
-Aluminized Steel Tube
-Elbow Kit
-Additional Joint/Hanger Pieces
-Aluminized Steel Tube c1w Radiant Treatment
-Side Wall Vent Kit

DISTRIBUTED BY:



 GENERAL SPECIFICATIONS
FOR MODELS CAL-20A AND CAL-50A

RATING: (Input)

(Natural and L.P. Gas)
CAL-20A 20,000 B.T.U./Hr.
CAL-40A 40,000 B.T.U./Hr.
CAL-50A 50,000 B.T.U./Hr.
(0-4500 ft. Above Sea Level


Gas Pressure at Manifold:
Natural Gas 3.5" W.C.
L.P. Gas 10.5" W.C.
Gas Connection Size 1/2" N.P.T

Gas Inlet Pressure:
GAS MINIMUM MAXIMUM
Nat. 4.5" W.C. 14.0" W.C.
L.P. 11.0" W.C. 14.0" W.C.
Flue Connection CAL-20A/40A 3"
CAL-50A 4"

ELECTRICAL RATING:
120V, 60Hz, .80 Amps
Appliance, 3 prong plug connection
24 Volt Low Voltage Thermostat
 STANDARD EQUIPMENT

Burner control housing is preassembled and prewired complete with the following: industry standard gas, electrical and venting connections, balanced air rotor, thermal overload protected motor, visual burner inspection sight glass, combustion and air proving safety switches, direct spark ignition control, low voltage thermostat connection, three prong appliance plug, polished aluminum standard reflector, radiant heat exchanger, tube couplers, joint pieces, joint/hanger pieces,  heat economizer baffle, aluminized combustion chamber.

OPTIONAL EQUIPMENT:
-Side Reflectors
-Lower Radiant Shield
-Side Wall Vent Terminal
-Thermostat and Lower Safety Screen

DISTRIBUTED BY:
SHIPPING WEIGHT: Approximately 100 lbs.